Sensors
Temperature
- Sensor technology: Silicon bandgap / Measuring unit: ºC
- Range: -40 - 145ºC / Resolution: 0,1ºC
- Accuracy: ± 0.5 ºC
- Lifespan1: >10 years
Relative Humidity
- Sensor technology: Capacitive / Unit of measurement: %RH
- Range: 0 - 100 %RH / Resolution: 1 %RH
- Accuracy: ± 2 %RH
- Lifespan: >10 years
CO2
- Sensor: NDIR / Unit of measurement: ppm
- Range: 400 - 10.000 ppm / Resolution: 1ppm
- Accuracy: ±(30 + 3% m.v.) ppm
- Lifespan: >10 years
TVOC
- Sensor: MOx / Unit of measurement: VOC Index Points (μg/m3 / ppm)1
- Range: 0 - 500 VOC Index Points / Resolution: 1 VOC Index Points
- Accuracy: ±15 VOC Index points or ±15% m.v., whichever is larger
- Lifespan: >10 years
PM2.5
- Sensor: Particle laser / Unit of measurement: μg/m3
- Range: 0 - 1.000 μg/m3 / Resolution: 1 μg/m3
- Accuracy: ± (5 μg/m3 + 5% m.v.) (0 -100 μg/m3 ), ±10% m.v. (101-1000 μg/m3 )
- Lifespan1: >10 years
PM10
- Sensor: Particle laser / Unit of measurement: μg/m3
- Range: 0 - 1.000 μg/m3 / Resolution: 1 μg/m3
- Accuracy: ±25 μg/m3 (0 -100 μg/m3), ±25% m.v. (101 - 1000 μg/m3)
- Lifespan: >10 years
PM4.0
- Sensor: Particle laser / Unit of measurement: μg/m3
- Range: 0 - 1.000 μg/m3 / Resolution: 1 μg/m3
- Accuracy: ±25 μg/m3 (0 -100 μg/m3), ±25% m.v. (101 - 1000 μg/m3)
- Lifespan: >10 years
PM1.0
- Sensor: Particle laser / Unit of measurement: μg/m3
- Range: 0 - 1.000 μg/m3 / Resolution: 1 μg/m3
- Accuracy: ± (5 μg/m3 + 5% m.v.) (0 -100 μg/m3 ), ±10% m.v. (101-1000 μg/m3 )
- Lifespan2: >10 years
Formaldehyde
- Sensor: Electrochemical / Unit of measure: ppb
- Range: 0 - 1000 ppb / Resolution: 1 ppb
- Accuracy: ±20 ppb or ±20% m.v., whichever is larger
- Lifespan: >6 years
O3
- Sensor: Electrochemical / Unit of measure: ppb
- Range: 0 - 5000 ppb / Resolution: 1 ppb
- Accuracy: ±10 ppb (0 - 500 ppb), ±2% m.v. (500 - 5000 ppb)
- Lifespan: >10 years
NO2
- Sensor: Electrochemical / Unit of measure: ppb
- Range: 0 - 2500 ppb / Resolution: 1 ppb
- Accuracy: ±20 ppb (0 - 500 ppb), ±(3% m.v. AND 5 ppb) (500 - 2500 ppb)
- Lifespan: >10 years
CO
- Sensor: Electrochemical / Unit of measure: ppm
- Range: 0 - 1000 ppm / Resolution: 0.1 ppm
- Accuracy: ±1 ppm (0 - 100 ppm), ±1% m.v. (100 - 1000 ppm)
- Lifespan2: >10 years
1 Measurements can be displayed either as relative values of Index points (recommended) or as concentrations in μg/m³ or ppb. The most suitable option can be selected from My inBiot. For more information, please contact us.
2 Lifespan is based on the average lifetime of the sensor, in which the specified accuracy is guaranteed. After the specified years, it is recommended to replace the sensor to ensure measurement accuracy.