Sensors

Temperature

  • Sensor technology: Silicon bandgap / Measuring unit: ºC
  • Range: -40 - 145ºC / Resolution: 0,1ºC
  • Accuracy: ± 0.5 ºC
  • Lifespan1: >10 years

Relative Humidity

  • Sensor technology: Capacitive / Unit of measurement: %RH
  • Range: 0 - 100 %RH / Resolution: 1 %RH
  • Accuracy: ± 2 %RH
  • Lifespan: >10 years

CO2

  • Sensor: NDIR / Unit of measurement: ppm
  • Range: 400 - 10.000 ppm / Resolution: 1ppm
  • Accuracy: ±(30 + 3% m.v.) ppm
  • Lifespan: >10 years

TVOC

  • Sensor: MOx / Unit of measurement: VOC Index Points (μg/m3 / ppm)1
  • Range: 0 - 500 VOC Index Points / Resolution: 1 VOC Index Points
  • Accuracy: ±15 VOC Index points or ±15% m.v., whichever is larger
  • Lifespan: >10 years

PM2.5

  • Sensor: Particle laser / Unit of measurement: μg/m3
  • Range: 0 - 1.000 μg/m3 / Resolution: 1 μg/m3
  • Accuracy: ± (5 μg/m3 + 5% m.v.) (0 -100 μg/m3 ), ±10% m.v. (101-1000 μg/m3 )
  • Lifespan1: >10 years

PM10

  • Sensor: Particle laser / Unit of measurement: μg/m3
  • Range: 0 - 1.000 μg/m3 / Resolution: 1 μg/m3
  • Accuracy: ±25 μg/m3 (0 -100 μg/m3), ±25% m.v. (101 - 1000 μg/m3)
  • Lifespan: >10 years

PM4.0

  • Sensor: Particle laser / Unit of measurement: μg/m3
  • Range: 0 - 1.000 μg/m3 / Resolution: 1 μg/m3
  • Accuracy: ±25 μg/m3 (0 -100 μg/m3), ±25% m.v. (101 - 1000 μg/m3)
  • Lifespan: >10 years

PM1.0

  • Sensor: Particle laser / Unit of measurement: μg/m3
  • Range: 0 - 1.000 μg/m3 / Resolution: 1 μg/m3
  • Accuracy: ± (5 μg/m3 + 5% m.v.) (0 -100 μg/m3 ), ±10% m.v. (101-1000 μg/m3 )
  • Lifespan2: >10 years

Formaldehyde

  • Sensor: Electrochemical / Unit of measure: ppb
  • Range: 0 - 1000 ppb / Resolution: 1 ppb
  • Accuracy: ±20 ppb or ±20% m.v., whichever is larger
  • Lifespan: >6 years

O3

  • Sensor: Electrochemical / Unit of measure: ppb
  • Range: 0 - 5000 ppb / Resolution: 1 ppb
  • Accuracy: ±10 ppb (0 - 500 ppb), ±2% m.v. (500 - 5000 ppb)
  • Lifespan: >10 years

NO2

  • Sensor: Electrochemical / Unit of measure: ppb
  • Range: 0 - 2500 ppb / Resolution: 1 ppb
  • Accuracy: ±20 ppb (0 - 500 ppb), ±(3% m.v. AND 5 ppb) (500 - 2500 ppb)
  • Lifespan: >10 years

CO

  • Sensor: Electrochemical / Unit of measure: ppm
  • Range: 0 - 1000 ppm / Resolution: 0.1 ppm
  • Accuracy: ±1 ppm (0 - 100 ppm), ±1% m.v. (100 - 1000 ppm)
  • Lifespan2: >10 years

1 Measurements can be displayed either as relative values of Index points (recommended) or as concentrations in μg/m³ or ppb. The most suitable option can be selected from My inBiot. For more information, please contact us.

2 Lifespan is based on the average lifetime of the sensor, in which the specified accuracy is guaranteed. After the specified years, it is recommended to replace the sensor to ensure measurement accuracy.

Has this article solved your doubts? Thank you for your response. There was a problem sending your response